Industrial Automation - Data collection - Business Solutions
 
 
 DAFI Gas Well Automation
 
Digital Air Flow Instrument      
 
 
  Flow Data has developed a unique data acquisition instrument - the DAFI (Digital Air flow Instrument). The DAFI calculates instantaneous volumetric air flow using Vortex flow technology, and is equipped to read data from other instruments on the job site, such as pressures, temperatures, alternate flow meters, etc. 

The DAFI displays data on an operator interface and records the data in its memory.  This data can be recorded and saved for up to nine months before downloading.  The sample rate for data logging can vary from once a minute to once an hour.

 
   Sample Uses
  • Under-balanced air drilling
  • Testing performance of air equipment
  • Calibration of air/nitrogen instruments
  • Foam /Mist air drilling
  • Pipeline dewatering

 

 
   Options Available for Data Retrieval
  • An on-board, fast thermal transfer printer
  • An HMI (Human Machine Interface) connection, that allows operators to view the data on a laptop
  • A DDE (Dynamic Data Exchange) connection for direct downloads into a Microsoft Excel Spreadsheet
  • Standard text log file creation
 
    Click to view DAFI Picture Gallery  
   
   
           
 
   Brief Description of DAFI Electronic Flow Computer/Data Acquisition System
   Basic D.A.F.I. Electronic Flow Computer  
  System Description:
      The D.A.F.I. electronic flow computer uses Vortex technology to calculate the volumetric flow rate of air flowing through a two inch meter run.  The flow rate is compensated for temperature, static pressure, and atmospheric pressure.  The flow rate and pressure are displayed locally in scfm and psig.
  Major Components
  • ” Schedule 80 meter run w/ 2” Fig 200 hammer union half on each end, 2000psig max working pressure
  • 2” Flow conditioner
  • Vortex Flow Instrument
  • Pressure Transmitter
  • Temperature Transmitter
   D.A.F.I. DAQ Electronic Flow Computer/Data Acquisition System
  System Description:
     
The D.A.F.I. electronic flow computer uses Vortex technology to calculate the volumetric flow rate of air flowing through a two inch meter run.  The flow rate is compensated for temperature, static pressure, and atmospheric pressure.  All of the current “live” data is displayed locally along with additional inputs such as fluid flow rate in GPM, typically from a Mist Pump, and remote or injection point pressure.  Additional inputs can be easily added, displayed and recorded.

     The data is stored in the PLC and is “broadcasted” live to a web page.  The “web page” signal is sent out through a built in Ethernet radio.  A second Ethernet radio receives the signal and sends it via a Cat. 5 cable to a laptop or PC.  Flow Data provides a laptop computer with the necessary software for displaying and reporting all of the data provided by the flow computer and its associated instruments.  A printer is also provided to print out reports locally.

  Major Components
  • 2” Schedule 80 meter run w/ 2” Fig 200 hammer union half on each end, 2000psig max working pressure
  • 2” Flow conditioner
  • Vortex Flow Instrument
  • Pressure Transmitter
  • Temperature Transmitter
  • Ethernet Radios, antennas, & cables
  • Fujitsu laptop PC
  • HP portable color printer
  • Rosemount 3051T Pressure Transmitter for remote pressure sensing
   D.A.F.I. DAQ Electronic Flow Computer/Data Acquisition System with 1” Magnetic Flow Meter
  System Description:
      Flow Data. Inc will provide all of the equipment described below.
  Major Components
  • All the major components described above in D.A.F.I. DAQ plus
  • 1" Magnetic Flow Meter
  • Cables, plugs, receptacles, and wiring necessary to read fluid flow rate (water) at rates between 0 and 50 gpm.
   D.A.F.I. DAQ Electronic Flow Computer/Data Acquisition System with 2” Automatic Bypass Valve
  System Description:
      Flow Data. Inc will provide all of the equipment described above in the basic D.A.F.I. DAQ description.  Flow Data. Inc will also provide a 2” Automatic Bypass Valve, cabling, wiring, and necessary additional programming.

      The Automatic Bypass Valve is designed and programmed to control the flow rate flowing through the flow computer to a specified “set point”.   The set point is specified by the operator and can be changed at the flow computer or from the laptop PC provided by Flow Data. Inc.   The bypass valve automatically opens and closes minutely to bypass excess air flow to maintain the set-point flow rate as it passed through the meter run.  The bypass valve is placed 20 to 30 feet “up-stream” of the flow computer.

  Major Components
  • All the major components described above in D.A.F.I. DAQ plus
  • 2" Automatic Bypass Valve, cabling, wiring, and necessary additional programming.
   D.A.F.I. Electronic Flow Computer with 2” Automatic Bypass Valve with 1” Magnetic Flow Meter
  System Description:
     
  Major Components
  • All the major components described above in D.A.F.I. DAQ plus
  • 2” Automatic Bypass Valve described above

  • 1” Magnetic Flow Meter described above.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    For more information, please call Kelly Farnsworth @ (970) 250-2520 or email: kelly@flow-data.com
     
Copyright © 2003-2004 Flow Data, Inc. 3184 Mesa Avenue • Grand Junction, CO 81504 • 970-523-7744